Alif Semiconductor /AE302F80C1557LE_CM55_HE_View /LPUART /UART_TAT

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as UART_TAT

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0DE_TO_RE0RE_TO_DE

Description

Turnaround Timing Register

Fields

DE_TO_RE

Driver Enable to Receiver Enable TurnAround time. Turnaround time (in terms of SCLK) for DE Deassertion to RE assertion: The actual time is the programmed value + 1.

RE_TO_DE

Receiver Enable to Driver Enable Turnaround time Turnaround time (in terms of SCLK) for RE deassertion to DE assertion:

  • If the UART_DET[DE_ASSERTION_TIME] field is 0, then the actual value is the programmed value + 3.
  • If the UART_DET[DE_ASSERTION_TIME] field is 1, then the actual value is the programmed value + 2.
  • If the UART_DET[DE_ASSERTION_TIME] field is greater than 1, then the actual value is the programmed value + 1.

Links

() ()